[特邀报告]Radiotherapy Planning QA: Opportunities Brought by the Artificial Intelligence and Monte Carlo

Radiotherapy Planning QA: Opportunities Brought by the Artificial Intelligence and Monte Carlo
编号:113 访问权限:仅限参会人 更新:2021-11-11 10:30:28 浏览:581次 特邀报告

报告开始:2021年11月14日 18:20 (Asia/Shanghai)

报告时间:25min

所在会议:[PS1] Plenary Session 1 » [CT1] Workshop on CT

暂无文件

摘要

At present, traditional dose verification in radiotherapy plan mainly uses homogeneous phantoms instead of patient for measurement verification. This method cannot evaluate the dose distribution in the human body. The development of artificial intelligence (AI) and Monte Carlo (MC) has brought opportunities in the dose verification.

For the two types of equipment of conventional electronic linear accelerator and nuclear magnetic guided accelerator, first of all, the source model of the electronic linear accelerator is established, and the commission of the measured machine measurement data is completed. Before the implementation of radiotherapy, the GPU-based MC calculation is used to generate the three-dimensional dose distribution for dose verification. Then in each fraction of radiotherapy, the MRI or CBCT images of the patient were obtained to generate the synthetic CT based on the AI, and the contours on the planned CT is propagated to the synthetic CT. The GPU-based MC calculation is used again to calculate the three-dimensional dose distribution on the pseudo CT according to the accelerator logfiles. Finally, the dose verification and tracking for patient are realized in the whole radiotherapy process.

Compared with Monaco Treatment Planning System (TPS) for 34 clinical cases of MR-guided radiotherapy, the γ-pass rates of ArcherQA and Monaco were greater than 90% (including 31 cases more than 95%) with the criteria of 3 mm/3% . Compared with Truebeam TPS for 40 clinical cases, compared with Eclipse, theγ-pass rates of ArcherQA and Truebeam were all greater than 95%. The average time of MC dose calculation for conventional radiotherapy plan and MR-guided radiotherapy plan were 34s and 80s, respectively. Compared with the traditional B-spline elastic registration, the accuracy and speed of the AI-based elastic registration have been greatly improved.

AI and MC can greatly improve the efficiency and accuracy of dose verification in radiotherapy plan, which are expected to be widely used in clinical radiotherapy in the future.

关键字
报告人
Xi Pei
Professor University of Science and Technology of China

* Associate professor, Institute of nuclear medical physics, University of Science and Technology of China

* General manager, Anhui Wisdom Technology Co., Ltd

发表评论
验证码 看不清楚,更换一张
全部评论

倒计时

  • 00

  • 00

  • 00

  • 00

重要日期

摘要提交日期:

2021/08/31

2021/10/25

全文投稿日期:  

2021/09/15

2021/10/25

录取通知日期: 

2021/09/30

2021/11/01

会议日期:   2021-11-12-2021-11-14

联系我们

杨巾英 13675518597
智德波 15056085235
高嵩 13121880288
曹乐 15910809908
会议邮箱: icmipe2021@ustc.edu.cn